Get quotes

Free tool · home and office RO

Reverse osmosis output: GPD to litres a day

Enter the membrane's GPD rating, your water temperature and pressure. The calculator gives the clean water a day you can expect, the waste water and how long the tank takes to fill.

Reverse osmosis output calculatorMembrane
GPD
°C
bar
bar
: 1
ℓ
0litres of clean water a day
At test conditions
0
Waste water a day
0
Time to fill the tank
0
250 ml glasses a day
0

GPD is US gallons a day (1 gallon = 3.785 ℓ) at the maker's test conditions, often 50 psi and 25 °C: check your membrane's datasheet. Temperature uses the membrane makers' temperature correction factor; pressure is scaled in a straight line from the test pressure, ignoring osmotic pressure, so treat the result as an estimate.

Reverse osmosis output calculatorFree tool · T-05
Rating
US gallons a day (GPD)
Test
Often 50 psi and 25 °C
1 gallon
3.785 litres
Cold water
Makes less clean water
Low pressure
Below 2.75 bar, add a pump

RO membranes are sold by their GPD rating: US gallons a day at the maker's test conditions. South African tap water is often colder than the 25 °C test and pressure varies by suburb, so a 75 GPD system rarely makes 284 litres a day. This calculator estimates what yours will make.

How the calculation works

The rated output in litres is GPD × 3.785. The membrane makes less in cold water: the calculator applies the temperature correction factor from the membrane makers' technical manual, which gives about 70% of the rated flow at 15 °C and 58% at 10 °C. Output also rises and falls with pressure, so the calculator scales it from the test pressure on the datasheet, often 50 psi (3.45 bar). It ignores osmotic pressure and tank back pressure, which both reduce real output a little more.

The waste ratio is the water sent to the drain for each litre of clean water. Many standard home systems run about 3 to 1. The US WaterSense label requires a system to deliver at least 30% of its feed water as clean water, which is a waste ratio of about 2.3 to 1 or better.

What size system do you need?

WHO puts drinking and food at 2.5 to 3 litres a person a day, so even a 50 GPD membrane in a cold Highveld winter makes more than a family uses. The storage tank and its refill time matter more for daily use: a 12 litre tank that takes three hours to refill can run out at a busy dinner. Offices, coffee shops and refill stations need larger membranes or commercial units.

Before you buy

Check your water pressure (a gauge on an outside tap) and your TDS with the TDS checker. Ask installers for the membrane rating, the waste ratio, whether a booster pump is included, the tank size and the cost of a year's filters. Use the filter replacement calculator to plan the changes, then request RO quotes.

Frequently asked questions

How many litres is 75 GPD?
75 US gallons a day is about 284 litres at the test conditions. At 15 °C and 3 bar, with a 50 psi test rating, expect roughly 170 litres a day, and less as the tank fills and back pressure builds.
Why does my RO system fill slowly in winter?
Membranes pass less water when it is cold. In a Gauteng or Free State winter, tap water can be 10 to 15 °C. The membrane makers' correction factor gives about 70% of the rated flow at 15 °C and 58% at 10 °C.
How much water does RO waste?
Many standard home systems send about 3 litres to the drain for each litre of clean water. Systems with the US WaterSense label must recover at least 30%, about 2.3 litres of waste per litre or less. The drain water can be collected for the garden.
Do I need a booster pump?
If your water pressure is below 2.75 bar (40 psi), the bottom of the usual operating range for home RO, or the system is fed from a tank, most home RO systems work much better with a booster pump.

Sources

Every figure the calculator uses comes from these published sources. Read the originals for the full context.

  1. FILMTEC Reverse Osmosis Membranes Technical Manual: temperature correction factor
  2. NIST Guide to the SI, Appendix B.8: gallon (US) to litre
  3. FILMTEC TW30-1812-50 home membrane datasheet: test conditions
  4. US EPA WaterSense specification for point-of-use RO systems (2024)
  5. Pentair GRO-2550 RO spec sheet: pressure range and filter changes
  6. WHO Technical Note 9: How much water is needed in emergencies (2013)

More water tools

Free quote request

Request water quotes

Fill in the order slip the way a supplier would ask for it: what you need, how many people drink, and where you are. Suppliers who deliver and install in your area quote you directly.

Order slipRef WS-05 · free, no obligation

01What you need

02Sizing (optional, it helps the quote)

FILTER TRAIN

Litres a week
-
Bottles
-
Dispensers
-
Estimate
-

A rule of thumb for the supplier, not a quote.

03Water and timing

04Request list (optional)

  1. 01
  2. 02
Up to 12 lines: units, bottles, filters or visits.
Needs and options

05Your details

Free and no obligation. By sending you agree that we may share your request with suitable water dispenser, delivery and treatment suppliers. See our privacy policy.

Get free water quotes