RO membranes are sold by their GPD rating: US gallons a day at the maker's test conditions. South African tap water is often colder than the 25 °C test and pressure varies by suburb, so a 75 GPD system rarely makes 284 litres a day. This calculator estimates what yours will make.
How the calculation works
The rated output in litres is GPD × 3.785. The membrane makes less in cold water: the calculator applies the temperature correction factor from the membrane makers' technical manual, which gives about 70% of the rated flow at 15 °C and 58% at 10 °C. Output also rises and falls with pressure, so the calculator scales it from the test pressure on the datasheet, often 50 psi (3.45 bar). It ignores osmotic pressure and tank back pressure, which both reduce real output a little more.
The waste ratio is the water sent to the drain for each litre of clean water. Many standard home systems run about 3 to 1. The US WaterSense label requires a system to deliver at least 30% of its feed water as clean water, which is a waste ratio of about 2.3 to 1 or better.
What size system do you need?
WHO puts drinking and food at 2.5 to 3 litres a person a day, so even a 50 GPD membrane in a cold Highveld winter makes more than a family uses. The storage tank and its refill time matter more for daily use: a 12 litre tank that takes three hours to refill can run out at a busy dinner. Offices, coffee shops and refill stations need larger membranes or commercial units.
Before you buy
Check your water pressure (a gauge on an outside tap) and your TDS with the TDS checker. Ask installers for the membrane rating, the waste ratio, whether a booster pump is included, the tank size and the cost of a year's filters. Use the filter replacement calculator to plan the changes, then request RO quotes.
Frequently asked questions
How many litres is 75 GPD?
Why does my RO system fill slowly in winter?
How much water does RO waste?
Do I need a booster pump?
Sources
Every figure the calculator uses comes from these published sources. Read the originals for the full context.
- FILMTEC Reverse Osmosis Membranes Technical Manual: temperature correction factor
- NIST Guide to the SI, Appendix B.8: gallon (US) to litre
- FILMTEC TW30-1812-50 home membrane datasheet: test conditions
- US EPA WaterSense specification for point-of-use RO systems (2024)
- Pentair GRO-2550 RO spec sheet: pressure range and filter changes
- WHO Technical Note 9: How much water is needed in emergencies (2013)
More water tools
- Office water cooler calculatorBottles a week, litres a month and how many dispensers an office, school or site needs.
- Daily water intake calculatorHow much water adults and children need a day, from food and drink, with extra for exercise.
- Water outage storage calculatorHow much water to store before a planned outage, in litres, bottles and tank size.
- TDS and water hardness checkerWhat a TDS or conductivity meter reading means for taste and the SANS 241 standard.
- Filter replacement calculatorWhen the sediment, carbon, RO membrane or UV lamp is due, by litres or by months.
- Dispenser electricity cost calculatorWhat a hot and cold water dispenser costs in electricity a month and a year.
- Water cost per litre calculatorCompare bottled delivery, refill stations and a filter or RO system per litre and per month.